Flow Sensor Ifm SDG350


IFM CATEGORIES

Flow Sensor Ifm sdg350

Flow Sensor SDG350

Brand: Ifm
Product Code: SDG2 1/2"METRIS PB DN65 SS

  • Accurate measurement of flow and consumption
  • Excellent precision, reproducibility, and measurement responsiveness
  • For the detection of pressurized air in industrial applications
  • Featuring switching output, analog output, and pulse output
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.6...143.9 m/s8...2011 m³/h
Connection for process flange DN65 in accordance with: DIN EN 10220
Application for commercial applications
Media pressurized air
Intermediate temperature value[°C] -10...60
Minimum force per unit area before bursting
64 bar6.4 MPa
Pressure classification
16 bar1.6 MPa
Precision (within the measurement range) class 141: ± (3 % MW + 0,3 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; reference conditions: inlet pipe length >= 113 cm outlet pipe length >= 15 cm; reference temperature value: 18..26 °C; norm volume flow 8...1155 m³/h; (norm volume flow DIN_ISO_2533 15 °C , 1013,25 mbar, 0 % r.H.)
Surrounding temperature value[°C] 0...60
Temperature for storage[°C] -20...85
Max. relative humidity of air[%] 90
Safety feature IP 65; IP 67

Reaction times

Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP[s] 0...5
Configuration options hysteresis / range; typically open / default closed; current/pulse output; display can be rotated and deactivated; display unit; cumulative counter
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2.5
Continuous current rating of the switching output DC[mA] 150; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 80
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Inputs reset function
Measuring span
0.6...143.9 m/s8...2011 m³/h
Show range
1.2...172.7 m/s16...2413 m³/h
In increments of
0.1 m/s1 m³/h
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations Digital Measurement Sensor (0x800A), Identification and Diagnostics (0x4000)
SIO mode yes
Necessary master port category A
Analog data process 8
Data binary process 2
Minimum process cycle duration[ms] 7.2
Supported DeviceIDs>
Mode of operationDeviceID
default1537

Download Specification for SDG350

Download PDF