Photoelectric Sensor Pepperl+Fuchs LA31/LK31/31/115
Pepperl+Fuchs Categories
Photoelectric Sensor LA31/LK31/31/115
Brand: Pepperl+Fuchs
Product Code:
Datasheet excerpt: Technical data of LA31/LK31/31/115
| Item Specification |
|---|
| Through-beam sensor, 30 m detection range, red light, dark-on operation, AC/DC variant, relay output, permanent cable |
Classifications
| System elements | ||
|---|---|---|
| Emitter | LA31/115 | |
| Receiver | LK31/31/115 | |
| Overall specifications | ||
| Operational sensing range | 0 ... 30 m | |
| detection range threshold | 43 m | |
| illumination source | LED | |
| Illumination type | modulated red light in the visible spectrum , 630 nm | |
| Alignment tool | Yellow indicator LED: 1. LED lights up: Adequate light signal detected, emitter and receiver are properly aligned 2. LED indicators: Attaining switching threshold 3. LED off: Light beam is disrupted or the alignment is incorrect |
|
| Size of the illumination spot | approximately 800 mm at a distance of 30 m | |
| angle of opening | Emitter: 0.5 ° , Transducer: 1.5 ° | |
| Ambient light threshold | 50000 Lux; in accordance with EN 60947-5-2 | |
| Parameters related to functional safety | ||
| MTTFd | 620 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | LED green: power activated | |
| operation indicator | Yellow indicator LED: 1. LED continuously illuminated: signal > 2 x switching threshold (functioning margin) 2. LED blinks: signal between 1 x switching threshold and 2 x switching threshold 3. LED off: signal < threshold point |
|
| Electrical parameters | ||
| Operational voltage | 24 ... 240 V AC 12 ... 240 V DC |
|
| No-load input current | Emitter: = 20 mA Transducer: = 20 mA |
|
| Energy usage | Emitter: = 1 VA Transducer: = 1 VA |
|
| Output | ||
| Type of switch | dark-on | |
| Output signal | Relay, 1 alternator | |
| Switching voltage level | max. 250 V AC/DC | |
| Switching capacity | max. 3 A | |
| Conversion power | DC: max. 150 W AC: max. 750 VA | |
| commutation frequency | = 20 Hz | |
| reaction time | = 25 ms | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Adherence to standards and directives | ||
| Compliance with standards | ||
| Standards | EN 62103 | |
| Certifications and approvals | ||
| Ingress protection rating | II, rated voltage = 250 V AC with pollution degree 1-2 as per IEC 60664-1, output circuit basic insulation of the input circuit in accordance with EN 50178, rated insulation voltage 240 V AC | |
| CCC certification | Approved by China Compulsory Certification (CCC) | |
| Environmental conditions | ||
| Ambient temperature | -25 ... 55 °C (-13 ... 131 °F) | |
| Ambient storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP67 | |
| Linkage | Emitter: 2 m permanently attached cable , 2-wire Transducer: 2 m permanently attached cable , 5-conductor |
|
| Material | ||
| Housing | PC (polycarbonate) | |
| optical surface | PMMA | |
| Mass | Emitter: 116 g Transducer: 131 g |
|
| Measurements | ||
| Height | 62 mm | |
| Width | 18 mm | |
| Depth | 35 mm | |