Datasheet excerpt: Technical data of LA39/LK39-Z/31/40a/116
| Item Specification |
|---|
| Through-beam sensor with a 20 m detection range, infrared light source, light/dark operation, AC/DC interoperability, relay contact output, Sensitivity calibration feature, timer function, and terminal chamber |
Classifications
| System elements | ||
|---|---|---|
| Emitter | LA39/116 | |
| Receiver | LK39-Z/31/40a/116 | |
| Overall specifications | ||
| Operational sensing range | 0 ... 20 m | |
| detection range threshold | 25 m | |
| modification range | 2 ... 25 m | |
| Reference point | receiver | |
| illumination source | IRED | |
| Illumination type | modulated infrared light | |
| Ambient light threshold | 10000 Lux | |
| Parameters related to functional safety | ||
| MTTFd | 916 a | |
| task duration (TM) | 20 a | |
| Diagnostic Range (DC) | 0 % | |
| Indicators/operation controls | ||
| Operational status indicator | Red LED (transmitter) | |
| operation indicator | Yellow indicator LED: status of switching LED red: pre-failure alert |
|
| control components | Detection distance calibrator, light-on/dark-on toggle switch | |
| control components | control switch for timing functions | |
| Electrical parameters | ||
| Operational voltage | 12 ... 240 V DC / 24 ... 240 V AC (50 ... 60 Hz) | |
| Ripple | 10 % | |
| No-load input current | = 60 mA receiver and emitter | |
| Ingress protection rating | II, rated voltage = 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution! The protection class 2 is applicable only when the terminal chamber is secured. The output circuit features basic insulation to the control circuit in accordance with IEC/EN 61140 |
|
| Energy usage | = 3 VA | |
| Delay time prior to availability | = 300 ms | |
| Output | ||
| Type of switch | light/dark on | |
| Output signal | 1 relay output | |
| Switching voltage level | max. 240 V AC ; 150 V DC | |
| Switching capacity | max. 3 A | |
| Conversion power | DC: max. 90 W AC: max. 750 VA | |
| commutation frequency | = 25 Hz | |
| reaction time | = 20 ms | |
| Timing feature | On/off delay or pulse extension selectable | |
| Compliance | ||
| Product specification | EN 60947-5-2 | |
| Certifications and approvals | ||
| CCC certification | Approved by China Compulsory Certification (CCC) | |
| Certifications | CE | |
| Environmental conditions | ||
| Ambient temperature | -25 ... 55 °C (-13 ... 131 °F) | |
| Ambient storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical characteristics | ||
| Protection等级 | IP54 | |
| Linkage | terminal chamber PG9, = 0.75 mm2 | |
| Material | ||
| Housing | PBT | |
| optical surface | PMMA | |
| Mass | Emitter: approx. 90 g receiver: approx. 110 g | |
| Measurements | ||
| Height | 64 mm | |
| Width | 25 mm | |
| Depth | 75 mm | |
| Overview information | ||
| Contents of shipment | installation assistance | |