Flow Sensor Ifm SD2000


IFM CATEGORIES

Flow Sensor Ifm sd2000

Flow Sensor SD2000

Brand: Ifm
Product Code: SDR21DGXFPKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • For the detection of pressurized air in industrial applications
  • Featuring switching output, analog output, and pulse output
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.3...95.2 m/s3...700 m³/h0.04...11.66 m³/min
Connection for process screw connection R 2 outdoor thread DN50
Application for commercial applications
Media pressurized air
Comment on medium
air quality according to ISO 8573-1
class 141
class 344
Intermediate temperature value[°C] 0...60
Pressure classification
16 bar1.6 MPa
Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP in increments[s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1

Software / programming

Configuration options Flow supervision; volume meter; preset counter; temperature value oversight; hysteresis / window; typically open / closed; current/pulse output; display can be adjusted and turned off; display unit; cumulative counter
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9 CDV
Configurations without profile
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 4.1
Supported DeviceIDs>
Mode of operationDeviceID
default270
Measuring span
0.3...95.2 m/s3...700 m³/h0.04...11.66 m³/min
Show range
0...114.2 m/s0...840 m³/h0...13.99 m³/min
Setpoint SP
0.7...95.2 m/s5...700 m³/h0.09...11.66 m³/min
Reset threshold rP
0.3...94.8 m/s2...697 m³/h0.04...11.61 m³/min
Analog initiation point ASP
0...71.4 m/s0...525 m³/h0...8.75 m³/min
Analog endpoint AEP
23.8...95.2 m/s175...700 m³/h2.91...11.66 m³/min
In increments of
0.1 m/s1 m³/h0.01 m³/min

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 110
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Reproducibility[% of the assessed value] ± 1,5
Precision (within the measurement range) ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50)
Surrounding temperature value[°C] 0...60
Temperature for storage[°C] -20...85
Max. relative humidity of air[%] 90
Safety feature IP 65

Download Specification for SD2000

Download PDF

RELATED PRODUCTS