Flow Sensor Ifm SD8001
IFM CATEGORIES
Flow Sensor SD8001
Brand: Ifm
Product Code: SDN11DGXFPKG/US-100
- Accurate monitoring of flow, consumption, and medium temperature value
- Excellent precision, reproducibility, and measurement responsiveness
- For the detection of pressurized air in industrial applications
- Featuring switching output, analog output, and pulse output
- Easily readable numerical display
Product characteristics
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 | |||
| Measuring span |
| |||
| Connection for process | screw connection 1" NPT with outdoor threading DN25 | |||
| Application | for commercial applications | |||
| Media | pressurized air | |||
| Comment on medium |
| |||
| Intermediate temperature value[°F] | 32...140 | |||
| Pressure classification |
| |||
| MAWP (for uses in compliance with CRN)[bar] | 16 | |||
| Response duration[s] | 0.1; (dAP = 0) | |||
| Damping process parameter dAP in increments[s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 | |||
| Weight[g] | 1979.5 | |||
| Housing | rectangular shape | |||
| measurements[mm] | 475 x 45 x 88.5 | |||
| Substance | PBT-GF20; NBR; PC; stainless steel (1.4306 / 304L); PTFE; brass-plated; aluminum powder-coated | |||
| Substances (contacted components) | stainless steel (1.4306 / 304L); FKM; glass-ceramics passivated; PEEK GF30; polyester; aluminum | |||
| Connection for process | screw connection 1" NPT with outdoor threading DN25 |
Software / programming
| Configuration options | Flow supervision; volume measuring device; preset counter; hysteresis / window; typically open / closed; current/pulse output; display can be adjusted and deactivated; display unit | ||
| Surrounding temperature value[°F] | 32...140 | ||
| Temperature for storage[°F] | -4...185 | ||
| Max. relative humidity of air[%] | 90 | ||
| Safety feature | IP 65 | ||
| Measuring span |
| ||
| Show range |
| ||
| Setpoint SP |
| ||
| Reset threshold rP |
| ||
| Analog initiation point ASP |
| ||
| Analog endpoint AEP |
| ||
| In increments of |
|
Inputs / outputs
| Total count of inputs and outputs | Count of digital outputs: 2; Count of analog outputs: 1 |
| Voltage for operation[V] | 19...30 DC; (to SELV/PELV) |
| Current draw[mA] | < 100 |
| Safety feature rating | III |
| Reverse polarity safeguard | yes |
| Activation delay time[s] | 0.5 |
| Overall count of outputs | 2 |
| Output response | output signal; analog output; pulse signal; (customizable) |
| Electrical engineering design | PNP |
| Count of digital outputs | 2 |
| Output feature | typically open / closed; (customizable) |
| Max. voltage drop at switching output DC[V] | 2 |
| Continuous current rating of the switching output DC[mA] | 250; (per output) |
| Total analog outputs | 1 |
| Analog current output[mA] | 4...20; (expandable) |
| Max. capacity[O] | 500 |
| Pulse output signal | consumption measurement device |
| Overcurrent protection | yes |
| Method of overcurrent protection | yes (momentary) |
| Overcurrent protection | yes |
| Reproducibility[% of the assessed value] | ± 1,5 |
| Precision (within the measurement range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN25) |
Download Specification for SD8001