Flow Sensor Ifm SM6001


IFM CATEGORIES

Flow Sensor Ifm sm6001

Flow Sensor SM6001

Brand: Ifm
Product Code: SMR12GGXFRKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • Featuring switching output, analog output, and pulse output
  • Easily readable numerical display

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
1.5...396 gph0.03...6.6 gpm
Connection for process screw connection G 1/2 with outdoor thread, DN15, and flat seal
System gold-plated terminals
Application Cumulative function; designed for industrial use
Setup connection to pipe via an adapter
Media Conductive fluids; water; aqueous media
Comment on medium
conductivity: = 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Intermediate temperature value[°F] 14...158
Pressure classification
16 bar232 psi1.6 MPa
MAWP (for uses in compliance with CRN)[bar] 17.7
Precision (within the measurement range) ± (0,8 % MW + 0,5 % MEW)
Reproducibility ± 0,2% MEW
Surrounding temperature value[°F] 14...140
Temperature for storage[°F] -13...176
Safety feature IP 67

Reaction times

Response duration[s] 0.15; (dAP = 0, T19)
Programmable delay time dS, dr[s] 0...50
Damping process parameter dAP[s] 0...5
Configuration options Flow supervision; volume measuring device; preset tally; temperature value oversight; hysteresis / window; typically open / closed; switching configuration; current/voltage/pulse output; startup delay; display can be turned off; display unit
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP/NPN
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 200
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Analog voltage output[V] 0...10; (adjustable)
Minimum load resistance[O] 2000
Pulse output signal flow measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] 95; (24 V)
Minimum insulation resistance[MO] 100; (500 V DC)
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 5
Measuring method magnetic-induction
Inputs reset function
Measuring span
1.5...396 gph0.03...6.6 gpm
Show range
-475.5...475.5 gph-7.925...7.925 gpm
Definition of detail level
0.5 gph0.01 gpm
Setpoint SP
3.5...396.5 gph0.06...6.6 gpm
Reset threshold rP
1.5...394 gph0.03...6.57 gpm
Analog initiation point ASP
0...318 gph0...5.3 gpm
Analog endpoint AEP
78...396 gph1.3...6.6 gpm
In increments of
0.5 gph0.01 gpm
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification; Device Diagnosis
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 5
Supported DeviceIDs>
Mode of operationDeviceID
default570

Download Specification for SM6001