Flow Sensor Ifm SD0523


IFM CATEGORIES

Flow Sensor Ifm sd0523

Flow Sensor SD0523

Brand: Ifm
Product Code: SDD11DGXFPKG/US-100

  • Accurate monitoring of flow, consumption, and medium temperature value
  • Excellent precision, reproducibility, and measurement responsiveness
  • For the detection of pressurized air in industrial applications
  • Featuring switching output, analog output, and pulse output
  • Customizable for internal pipe diameters

Share on:

Product characteristics

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Measuring span
0.5...143.9 m/s8...2110 m³/h0.12...35.18 m³/min
Connection for process screw connection G 1 with internal thread
Setup Customizable for internal pipe diameters; (38...254 mm)
Media pressurized air
Intermediate temperature value[°C] 0...60
Pressure classification
16 bar232 psi1.6 MPa
MAWP (for uses in compliance with CRN)[bar] 16
Response duration[s] 0.1; (dAP = 0)
Damping process parameter dAP in increments[s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1

Software / programming

Configuration options Flow supervision; volume meter; preset counter; temperature value oversight; hysteresis / window; typically open / closed; current/pulse output; display can be adjusted and turned off; display unit; cumulative counter
communication interface IO-Link
Mode of transmission COM2 (38,4 kBaud)
IO-Link version 1.1
SDCI specification IEC 61131-9
Configurations Intelligent Sensor: Data Process Variable; Device Identification
SIO mode yes
Necessary master port category A
Analog data process 3
Data binary process 2
Minimum process cycle duration[ms] 5
Supported DeviceIDs>
Mode of operationDeviceID
default381
Measuring span Measuring/setting range; Flow tracking; The values are applicable at: Ø 72 mm
Measuring span
0.5...143.9 m/s8...2110 m³/h0.12...35.18 m³/min
Show range
0...172.7 m/s0...2532 m³/h0...42.22 m³/min
Definition of detail level
0.1 m/s2 m³/h0.02 m³/min
Setpoint SP
1.2...143.9 m/s18...2110 m³/h0.28...35.18 m³/min
Reset threshold rP
0.5...143.2 m/s6...2100 m³/h0.12...35 m³/min
Analog initiation point ASP
0...107.9 m/s0...1582 m³/h0...26.38 m³/min
Analog endpoint AEP
36...143.9 m/s528...2110 m³/h8.8...35.18 m³/min
In increments of
0.1 m/s2 m³/h0.02 m³/min

Inputs / outputs

Total count of inputs and outputs Count of digital outputs: 2; Count of analog outputs: 1
Voltage for operation[V] 18...30 DC; (to SELV/PELV)
Current draw[mA] < 110
Safety feature rating III
Reverse polarity safeguard yes
Activation delay time[s] 1
Overall count of outputs 2
Output response output signal; analog output; pulse signal; IO-Link; (customizable)
Electrical engineering design PNP
Count of digital outputs 2
Output feature typically open / closed; (customizable)
Max. voltage drop at switching output DC[V] 2
Continuous current rating of the switching output DC[mA] 250; (per output)
Total analog outputs 1
Analog current output[mA] 4...20; (expandable)
Max. capacity[O] 500
Pulse output signal consumption measurement device
Overcurrent protection yes
Method of overcurrent protection yes (momentary)
Overcurrent protection yes
Reproducibility[% of the assessed value] ± 1,5
Precision (within the measurement range) ± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; norm volume flow: 50...850 Nm³/h)
Surrounding temperature value[°C] 0...60
Temperature for storage[°C] -20...85
Max. relative humidity of air[%] 90
Safety feature IP 65

Download Specification for SD0523

Download PDF

RELATED PRODUCTS